FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

252762003: Interference pattern electromyography analysis (procedure)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2972523012 Interference pattern electromyography analysis en Synonym Active Case insensitive SNOMED CT core
2972702016 Interference pattern electromyography analysis (procedure) en Fully specified name Active Case insensitive SNOMED CT core
376483012 Interference pattern EMG analysis en Synonym Active Initial character case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site Skeletal muscle system structure false Inferred relationship Some 3
Interference pattern EMG analysis Procedure site Peripheral nervous system structure true Inferred relationship Some 2
Interference pattern EMG analysis Procedure site Muscle structure false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Procedure site Skeletal muscle structure false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Using device Electromyographic monitor and recorder false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site - Direct Neuron-muscle motor unit false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site - Direct Structure of nervous system false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Procedure site - Direct Structure of nervous system true Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 3
Interference pattern EMG analysis Using device Electromyographic monitor and recorder true Inferred relationship Some 3
Interference pattern EMG analysis Procedure site Neuromuscular junction false Inferred relationship Some
Interference pattern EMG analysis Method Investigation - action false Inferred relationship Some
Interference pattern EMG analysis Has intent Diagnostic intent true Inferred relationship Some 1
Interference pattern EMG analysis Has intent Therapeutic false Inferred relationship Some
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 4
Interference pattern EMG analysis Using device Electromyographic monitor and recorder true Inferred relationship Some 4
Interference pattern EMG analysis Procedure site - Direct Structure of neuron-muscle motor unit true Inferred relationship Some 4
Interference pattern EMG analysis Is a Quantitative EMG analysis true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Back to Start