FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

234230005: Implanted defibrillator electrode infection (disorder)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
350921014 Implanted defibrillator electrode infection en Synonym Active Case insensitive SNOMED CT core
622522012 Implanted defibrillator electrode infection (disorder) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implanted defibrillator electrode infection Is a Infection by site false Inferred relationship Some
Implanted defibrillator electrode infection Temporally follows Surgical procedure false Inferred relationship Some
Implanted defibrillator electrode infection Is a Infectious disease of cardiovascular system false Inferred relationship Some
Implanted defibrillator electrode infection Is a Infection as complication of medical care false Inferred relationship Some
Implanted defibrillator electrode infection Causative agent Infectious agent false Inferred relationship Some
Implanted defibrillator electrode infection Temporally follows Automatic defibrillator procedure false Inferred relationship Some
Implanted defibrillator electrode infection Temporally follows Surgical procedure false Inferred relationship Some
Implanted defibrillator electrode infection Is a Infectious disease of heart false Inferred relationship Some
Implanted defibrillator electrode infection Finding site Cardiovascular system subdivision false Inferred relationship Some
Implanted defibrillator electrode infection Is a Infectious disease of cardiovascular system false Inferred relationship Some
Implanted defibrillator electrode infection Following Surgical procedure false Inferred relationship Some
Implanted defibrillator electrode infection Finding site Structure of cardiovascular system false Inferred relationship Some
Implanted defibrillator electrode infection Following Implantation of prosthetic device false Inferred relationship Some
Implanted defibrillator electrode infection Associated with Surgical procedure false Inferred relationship Some
Implanted defibrillator electrode infection Pathological process Infectious process true Inferred relationship Some 1
Implanted defibrillator electrode infection Associated with Implantable defibrillator true Inferred relationship Some 3
Implanted defibrillator electrode infection Associated with Procedure false Inferred relationship Some
Implanted defibrillator electrode infection Is a Infection associated with cardiac implant true Inferred relationship Some
Implanted defibrillator electrode infection Is a Disorder of implanted cardiac defibrillator electrode true Inferred relationship Some
Implanted defibrillator electrode infection Temporally follows Procedure false Inferred relationship Some
Implanted defibrillator electrode infection Causative agent Microorganism false Inferred relationship Some
Implanted defibrillator electrode infection Finding site Cardiac structure false Inferred relationship Some
Implanted defibrillator electrode infection Due to Procedure false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Australian emergency department reference set

Clinical finding foundation reference set

Problem/Diagnosis reference set

Back to Start