FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

233177000: Insertion of epicardial electrode for temporary cardiac pacing (procedure)


Status: current, Defined. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
349346016 Insertion of epicardial electrode for temporary cardiac pacing en Synonym Active Case insensitive SNOMED CT core
349347013 Epicardial pacing en Synonym Active Case insensitive SNOMED CT core
621331013 Insertion of epicardial electrode for temporary cardiac pacing (procedure) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Procedure site - Direct Structure of heart false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Direct device Cardiac pacemaker electrode false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action false Inferred relationship Some 3
Insertion of epicardial electrode for temporary cardiac pacing Procedure device Cardiac pacemaker false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Procedure site - Indirect Structure of heart false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Procedure site - Indirect Cardiac ventricular structure false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Procedure device Cardiac pacemaker false Inferred relationship Some
Insertion of epicardial electrode for temporary cardiac pacing Procedure site - Indirect Cardiac ventricular structure true Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Direct device Epicardial pacemaker electrode true Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Method Insertion - action true Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Is a Insertion of temporary cardiac pacemaker true Inferred relationship Some
Insertion of epicardial electrode for temporary cardiac pacing Method Implantation - action false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Direct device Cardiac pacemaker false Inferred relationship Some 2
Insertion of epicardial electrode for temporary cardiac pacing Procedure site Cardiac ventricular structure false Inferred relationship Some 1
Insertion of epicardial electrode for temporary cardiac pacing Has intent Transitory false Inferred relationship Some
Insertion of epicardial electrode for temporary cardiac pacing Direct device Epicardial pacemaker electrode false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Back to Start