FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

231039001: Implantation of neurostimulator electrode onto spinal nerve root (procedure)


Status: current, Defined. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
346127013 Implantation of neurostimulator electrode onto spinal nerve root en Synonym Active Case insensitive SNOMED CT core
618924013 Implantation of neurostimulator electrode onto spinal nerve root (procedure) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of neurostimulator electrode onto spinal nerve root Is a Biomedical equipment procedure false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Is a Insertion procedure false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Is a Procedure on spine true Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Method Insertion - action false Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Method Stimulation - action false Inferred relationship Some 2
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Peripheral nerve structure false Inferred relationship Some 2
Implantation of neurostimulator electrode onto spinal nerve root Is a Implantation of electrode into peripheral nerve true Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Structure of nervous system false Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Procedure device Neurostimulation device false Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Procedure on organ true Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Procedure site - Indirect Spinal nerve root structure false Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Peripheral nerve neurostimulator electrode procedures true Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Procedure site - Indirect Spinal nerve root structure true Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Method Insertion - action false Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulator electrode true Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Is a Neurostimulation procedures of spinal nerve root false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Is a Insertion of pacemaker into peripheral nerve false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Method Implantation - action true Inferred relationship Some 1
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Spinal nerve root structure false Inferred relationship Some 2
Implantation of neurostimulator electrode onto spinal nerve root Procedure site Spinal cord root and/or ganglion false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulation device false Inferred relationship Some
Implantation of neurostimulator electrode onto spinal nerve root Direct device Neurostimulator electrode false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Description inactivation indicator reference set

REPLACED BY association reference set

Back to Start