FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

18479002: Testicular imaging with vascular flow (procedure)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
31179013 Testicular imaging with vascular flow en Synonym Active Case insensitive SNOMED CT core
745944011 Testicular imaging with vascular flow (procedure) en Fully specified name Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Testicular imaging with vascular flow Is a Trunk angiography true Inferred relationship Some
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 3
Testicular imaging with vascular flow Method Structure of cardiovascular system false Inferred relationship Some 1
Testicular imaging with vascular flow Is a Radionuclide study of vascular system true Inferred relationship Some
Testicular imaging with vascular flow Is a Radionuclide study of scrotum false Inferred relationship Some
Testicular imaging with vascular flow Is a Medical procedure on genitourinary system false Inferred relationship Some
Testicular imaging with vascular flow Is a Testicular imaging true Inferred relationship Some
Testicular imaging with vascular flow Method Introduction - action false Inferred relationship Some 3
Testicular imaging with vascular flow Method Imaging - action false Inferred relationship Some 2
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 2
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 2
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 1
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 2
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 1
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 3
Testicular imaging with vascular flow Is a Urogenital system angiography false Inferred relationship Some
Testicular imaging with vascular flow Is a Nuclear medicine study by site false Inferred relationship Some
Testicular imaging with vascular flow Is a Nuclear medicine diagnostic procedure on genitourinary system false Inferred relationship Some
Testicular imaging with vascular flow Is a Pelvic angiography false Inferred relationship Some
Testicular imaging with vascular flow Procedure site Vascular structure of testis false Inferred relationship Some 1
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 1
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 3
Testicular imaging with vascular flow Procedure site Body system structure false Inferred relationship Some 3
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 1
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 3
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 1
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 3
Testicular imaging with vascular flow Is a Radionuclide male genital system study false Inferred relationship Some
Testicular imaging with vascular flow Procedure site - Direct Testis structure false Inferred relationship Some 2
Testicular imaging with vascular flow Procedure site - Direct Vascular structure of testis false Inferred relationship Some 1
Testicular imaging with vascular flow Using substance Radioactive isotope false Inferred relationship Some 1
Testicular imaging with vascular flow Using substance Radioactive isotope true Inferred relationship Some 1
Testicular imaging with vascular flow Procedure site - Direct Vascular structure of testis true Inferred relationship Some 1
Testicular imaging with vascular flow Method Radionuclide imaging - action true Inferred relationship Some 1
Testicular imaging with vascular flow Method Imaging - action true Inferred relationship Some 2
Testicular imaging with vascular flow Procedure site - Direct Testis structure true Inferred relationship Some 2
Testicular imaging with vascular flow Procedure site Testis structure false Inferred relationship Some 2
Testicular imaging with vascular flow Procedure site Blood vessel structure false Inferred relationship Some 2
Testicular imaging with vascular flow Procedure site Scrotal structure false Inferred relationship Some 1
Testicular imaging with vascular flow Procedure site Male genital structure false Inferred relationship Some 2
Testicular imaging with vascular flow Direct substance Radioactive isotope false Inferred relationship Some 4
Testicular imaging with vascular flow Method Investigation - action false Inferred relationship Some
Testicular imaging with vascular flow Has intent Diagnostic intent false Inferred relationship Some
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 1
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 2
Testicular imaging with vascular flow Method Radionuclide imaging - action false Inferred relationship Some 3
Testicular imaging with vascular flow Procedure site Structure of cardiovascular system false Inferred relationship Some 3
Testicular imaging with vascular flow Measures Vascular flow false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Imaging procedure reference set

Back to Start