FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

12715008: Implantation of electrode into brain (procedure)


Status: current, Defined. Date: 31-Jan 2005. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
21830013 Implantation of electrode into brain en Synonym Active Case insensitive SNOMED CT core
21831012 Intracranial implantation of electrode en Synonym Active Case insensitive SNOMED CT core
731204019 Implantation of electrode into brain (procedure) en Fully specified name Active Case insensitive SNOMED CT core


2 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of electrode into brain Method Implantation - action true Inferred relationship Some 1
Implantation of electrode into brain Is a Implantation procedure true Inferred relationship Some
Implantation of electrode into brain Is a Implantation false Inferred relationship Some
Implantation of electrode into brain Is a Procedure on brain true Inferred relationship Some
Implantation of electrode into brain Procedure site Body structure false Inferred relationship Some 2
Implantation of electrode into brain Method Insertion - action false Inferred relationship Some 1
Implantation of electrode into brain Direct device Implant false Inferred relationship Some
Implantation of electrode into brain Is a Procedure categorised by device involved false Inferred relationship Some
Implantation of electrode into brain Procedure site - Indirect Brain structure false Inferred relationship Some 1
Implantation of electrode into brain Direct device Electrode false Inferred relationship Some 1
Implantation of electrode into brain Is a Brain implantation false Inferred relationship Some
Implantation of electrode into brain Direct device Electrode true Inferred relationship Some 1
Implantation of electrode into brain Method Insertion - action false Inferred relationship Some 1
Implantation of electrode into brain Procedure site - Indirect Brain structure true Inferred relationship Some 1
Implantation of electrode into brain Is a Biomedical equipment procedure true Inferred relationship Some
Implantation of electrode into brain Procedure site Brain structure false Inferred relationship Some 1
Implantation of electrode into brain Method Implantation - action false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group
Percutaneous implantation of neurostimulator electrodes into cranial nerve Is a False Implantation of electrode into brain Inferred relationship Some
Implantation of electronic stimulator in brain Is a False Implantation of electrode into brain Inferred relationship Some
Placement of brain surface electrode for electroencephalography Is a False Implantation of electrode into brain Inferred relationship Some
Placement of depth electrode into brain for electroencephalography Is a False Implantation of electrode into brain Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance Is a True Implantation of electrode into brain Inferred relationship Some

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Back to Start