FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

737085003: Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2018. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3526755013 Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3526756014 Fluoroscopy guided percutaneous insertion of bioresorbable stent into coronary artery en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3543039013 Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Procedure on coronary arteries true Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Fluoroscopy guided vascular stent procedure true Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Insertion of arterial stent true Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) investigation cardiovasculaire true Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Coronary artery implantation (procedure) false Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Insertion of stent using fluoroscopic guidance (procedure) true Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) est un(e) (attribut) Biomedical equipment procedure (procedure) false Inferred relationship Some
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) accès (attribut) Percutaneous approach true Inferred relationship Some 2
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) méthode (attribut) action : insertion true Inferred relationship Some 2
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) Direct device Bioabsorbable vascular stent true Inferred relationship Some 2
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) structure d'une artère coronaire true Inferred relationship Some 2
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) méthode (attribut) Fluoroscopic imaging - action true Inferred relationship Some 3
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) a pour but (attribut) Guidance intent (qualifier value) true Inferred relationship Some 3
Percutaneous insertion of bioresorbable stent into coronary artery using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) structure d'une artère coronaire true Inferred relationship Some 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start