FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

45965006: Implantation of automatic cardioverter/defibrillator, total system (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Oct 2021. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    2913327016 Implantation of automatic cardioverter/defibrillator, total system (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
    2914785018 Implantation of automatic cardioverter/defibrillator, total system en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
    76641014 Implantation of automatic cardioverter/defibrillator, total system (AICD) en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Implantation of automatic cardioverter/defibrillator, total system (procedure) est un(e) (attribut) Implantation to cardiovascular system false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) localisation de l'intervention (attribut) structure corporelle false Inferred relationship Some 2
    Implantation of automatic cardioverter/defibrillator, total system (procedure) méthode (attribut) action : insertion false Inferred relationship Some 1
    Implantation of automatic cardioverter/defibrillator, total system (procedure) est un(e) (attribut) intervention sur un stimulateur cardiaque permanent false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) est un(e) (attribut) Procedure on heart false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) est un(e) (attribut) Thorax implantation false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) est un(e) (attribut) Heart implantation false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) Procedure site - Indirect (attribute) cœur false Inferred relationship Some 1
    Implantation of automatic cardioverter/defibrillator, total system (procedure) méthode (attribut) action : insertion false Inferred relationship Some 1
    Implantation of automatic cardioverter/defibrillator, total system (procedure) Procedure site - Indirect (attribute) cœur false Inferred relationship Some 1
    Implantation of automatic cardioverter/defibrillator, total system (procedure) localisation de l'intervention (attribut) cœur false Inferred relationship Some 1
    Implantation of automatic cardioverter/defibrillator, total system (procedure) a pour but (attribut) permanent false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) Direct device stimulateur cardiaque false Inferred relationship Some
    Implantation of automatic cardioverter/defibrillator, total system (procedure) méthode (attribut) Implantation - action false Inferred relationship Some 2

    Inbound Relationships Type Active Source Characteristic Refinability Group
    Automatic defibrillator procedure est un(e) (attribut) False Implantation of automatic cardioverter/defibrillator, total system (procedure) Inferred relationship Some

    Reference Sets

    Concept inactivation indicator reference set

    SAME AS association reference set (foundation metadata concept)