FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

450821005: Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) est un(e) (attribut) guidage fluoroscopique true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) méthode (attribut) Fluoroscopic imaging - action false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) a pour but (attribut) Guidance intent (qualifier value) false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) est un(e) (attribut) Automatic defibrillator procedure true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) est un(e) (attribut) Replacement of device (procedure) true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) est un(e) (attribut) Removal of cardiac pacemaker true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) méthode (attribut) action : remplacement false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device défibrillateur interne false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) méthode (attribut) action : remplacement true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) méthode (attribut) Fluoroscopic imaging - action true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) a pour but (attribut) Guidance intent (qualifier value) true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device défibrillateur interne true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start