Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Apr 2022. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2879486017 | Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2881530014 | Insertion of electrocardiography loop recorder using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | est un(e) (attribut) | intervention selon le dispositif | false | Inferred relationship | Some | ||
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | est un(e) (attribut) | Insertion of therapeutic device | false | Inferred relationship | Some | ||
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | est un(e) (attribut) | Insertion using fluoroscopic guidance (procedure) | false | Inferred relationship | Some | ||
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | Direct device | implant cardiaque | false | Inferred relationship | Some | 2 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | méthode (attribut) | action : insertion | false | Inferred relationship | Some | 2 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | méthode (attribut) | Fluoroscopic imaging - action | false | Inferred relationship | Some | 1 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | a pour but (attribut) | Guidance intent (qualifier value) | false | Inferred relationship | Some | 1 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | a pour but (attribut) | Guidance intent (qualifier value) | false | Inferred relationship | Some | 1 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | méthode (attribut) | action : insertion | false | Inferred relationship | Some | 2 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | Direct device | implant cardiaque | false | Inferred relationship | Some | 2 | |
Insertion of electrocardiography loop recorder using fluoroscopic guidance (procedure) | méthode (attribut) | Fluoroscopic imaging - action | false | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets
Concept inactivation indicator reference set
SAME AS association reference set (foundation metadata concept)