FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

441873006: Percutaneous replacement of aortic valve using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2009. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2818097019 Percutaneous replacement of aortic valve using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2818098012 Percutaneous replacement of aortic valve using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Transcatheter aortic valve replacement (procedure) false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance méthode (attribut) Surgical replacement - action true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Using access device (attribute) Vascular catheter true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Catheter procedure true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Prosthetic replacement of heart valve true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) intervention selon le dispositif false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) guidage fluoroscopique true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Angiocardiography of left heart (procedure) false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Cardiac fluoroscopy true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Procedure on heart valve false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) Replacement procedure false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance méthode (attribut) Fluoroscopic imaging - action true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Using device (attribute) prothèse valvulaire aortique true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance accès (attribut) Percutaneous approach true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance méthode (attribut) action : remplacement false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance a pour but (attribut) Guidance intent (qualifier value) true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) valve aortique (structure corporelle) true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) valve aortique (structure corporelle) true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) valve aortique (structure corporelle) false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance accès (attribut) Percutaneous approach false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Using device (attribute) prothèse valvulaire aortique false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance est un(e) (attribut) remplacement de la valve aortique true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance méthode (attribut) Surgical replacement - action false Inferred relationship Some 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start