FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

30050007: Inhalation anesthesia, machine system, semi-closed, no rebreathing of primary agent (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
484468010 Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
50282012 Inhalation anesthesia, machine system, semi-closed, no rebreathing of primary agent en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
761012014 Inhalation anesthesia, machine system, semi-closed, no rebreathing of primary agent (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent Procedure site - Direct (attribute) structure de l'appareil respiratoire true Inferred relationship Some 2
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent est un(e) (attribut) anesthésie générale (intervention) true Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent est un(e) (attribut) respiration artificielle (intervention) true Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Introduction - action false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent substance utilisée (attribut) General inhalation anesthetic (substance) false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent a pour objet (attribut) Ventilation finding false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent a pour objet (attribut) Ventilatory assistance false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent est un(e) (attribut) Administration of anesthesia for procedure (procedure) false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent localisation de l'intervention (attribut) Structure of central nervous system (body structure) false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Administration - action false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent substance utilisée (attribut) General anesthetic (substance) false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent Procedure site - Direct (attribute) structure de l'appareil respiratoire false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Infusion - action false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent Procedure site - Indirect (attribute) Structure of central nervous system (body structure) false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Introduction of substance false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent localisation de l'intervention (attribut) structure de l'appareil respiratoire false Inferred relationship Some 2
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Administration - action false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent substance utilisée (attribut) General anesthetic (substance) false Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Administration - action true Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent substance utilisée (attribut) General anesthetic (substance) true Inferred relationship Some 1
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent localisation de l'intervention (attribut) structure de l'appareil respiratoire false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent a pour but (attribut) thérapeutique false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent substance utilisée (attribut) General inhalation anesthetic false Inferred relationship Some
Inhalation anaesthesia, machine system, semi-closed, no rebreathing of primary agent méthode (attribut) Assisting - action false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Canada English language reference set (foundation metadata concept)

Description inactivation indicator reference set

GB English

US English

Back to Start