FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

252624005: Evoked oto-acoustic emission measurement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
376282016 Cochlear echo test en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
376283014 Kemp echo test en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
376285019 Evoked oto-acoustic emission measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3765022018 EOAE - evoked oto-acoustic emission measurement en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
643277019 Evoked oto-acoustic emission measurement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Evoked oto-acoustic emission measurement est un(e) (attribut) examen d'un système corporel true Inferred relationship Some
Evoked oto-acoustic emission measurement est un(e) (attribut) Functional assessment true Inferred relationship Some
Evoked oto-acoustic emission measurement méthode (attribut) Functional assessment - action true Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) Evaluation - action false Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) Evaluation - action false Inferred relationship Some 2
Evoked oto-acoustic emission measurement méthode (attribut) action : test false Inferred relationship Some 1
Evoked oto-acoustic emission measurement Procedure site - Direct (attribute) structure du système auditif false Inferred relationship Some 1
Evoked oto-acoustic emission measurement Procedure site - Direct (attribute) structure du système auditif true Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) action : test false Inferred relationship Some 1
Evoked oto-acoustic emission measurement Procedure site - Direct (attribute) structure du système auditif false Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) Evaluation - action false Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) Evaluation - action false Inferred relationship Some 1
Evoked oto-acoustic emission measurement localisation de l'intervention (attribut) oreille false Inferred relationship Some 1
Evoked oto-acoustic emission measurement méthode (attribut) Investigation - action false Inferred relationship Some
Evoked oto-acoustic emission measurement a pour but (attribut) à visée diagnostique true Inferred relationship Some 2
Evoked oto-acoustic emission measurement localisation de l'intervention (attribut) tractus respiratoire supérieur (structure corporelle) false Inferred relationship Some 2
Evoked oto-acoustic emission measurement est un(e) (attribut) Oto-acoustic emission test true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Programmable oto-acoustic emissions est un(e) (attribut) True Evoked oto-acoustic emission measurement Inferred relationship Some

This concept is not in any reference sets

Back to Start