FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

234213008: Pacemaker electrode lead displacement (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
350901013 Pacemaker electrode lead displacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
622503015 Pacemaker electrode lead displacement (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Pacemaker electrode lead displacement associé à (attribut) implant false Inferred relationship Some 3
Pacemaker electrode lead displacement Temporally follows Surgical procedure (procedure) false Inferred relationship Some
Pacemaker electrode lead displacement Temporally follows intervention sur un stimulateur cardiaque false Inferred relationship Some
Pacemaker electrode lead displacement Temporally follows Surgical procedure (procedure) false Inferred relationship Some
Pacemaker electrode lead displacement Temporally follows Implantation false Inferred relationship Some
Pacemaker electrode lead displacement localisation d'une constatation (attribut) Cardiovascular system subdivision false Inferred relationship Some
Pacemaker electrode lead displacement After Surgical procedure (procedure) false Inferred relationship Some
Pacemaker electrode lead displacement After intervention sur un stimulateur cardiaque false Inferred relationship Some
Pacemaker electrode lead displacement After Implantation of prosthetic device false Inferred relationship Some
Pacemaker electrode lead displacement localisation d'une constatation (attribut) Structure of cardiovascular system (body structure) false Inferred relationship Some
Pacemaker electrode lead displacement associé à (attribut) Surgical procedure (procedure) false Inferred relationship Some
Pacemaker electrode lead displacement associé à (attribut) Cardiac pacemaker lead true Inferred relationship Some 2
Pacemaker electrode lead displacement associé à (attribut) Procedure false Inferred relationship Some
Pacemaker electrode lead displacement est un(e) (attribut) Complication associated with cardiac pacemaker lead (disorder) true Inferred relationship Some
Pacemaker electrode lead displacement est un(e) (attribut) Disorder of cardiac pacemaker electrode false Inferred relationship Some
Pacemaker electrode lead displacement Temporally follows Procedure false Inferred relationship Some
Pacemaker electrode lead displacement Causative agent stimulateur cardiaque false Inferred relationship Some
Pacemaker electrode lead displacement localisation d'une constatation (attribut) Cardiac structure false Inferred relationship Some
Pacemaker electrode lead displacement Causative agent Electrode false Inferred relationship Some
Pacemaker electrode lead displacement Due to Procedure false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Dislodgement of cardiac pacemaker ventricular lead (disorder) est un(e) (attribut) True Pacemaker electrode lead displacement Inferred relationship Some

This concept is not in any reference sets

Back to Start