FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

104847001: Oxygen saturation measurement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
168842013 Oxygen saturation measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
168843015 Hemoglobin saturation measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
168844014 Haemoglobin saturation measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
168845010 Oxygen content measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
566745016 Oxygen saturation measurement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


17 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Oxygen saturation measurement est un(e) (attribut) Analysis of arterial blood gases and pH (procedure) false Inferred relationship Some
Oxygen saturation measurement élément (attribut) Hydrogen ion concentration (observable entity) false Inferred relationship Some
Oxygen saturation measurement élément (attribut) oxygène false Inferred relationship Some
Oxygen saturation measurement a un échantillon (attribut) Arterial blood specimen false Inferred relationship Some
Oxygen saturation measurement méthode (attribut) Evaluation - action false Inferred relationship Some
Oxygen saturation measurement méthode (attribut) action : mesure false Inferred relationship Some
Oxygen saturation measurement est un(e) (attribut) Blood gas analysis true Inferred relationship Some
Oxygen saturation measurement élément (attribut) substance false Inferred relationship Some
Oxygen saturation measurement méthode (attribut) Investigation - action false Inferred relationship Some
Oxygen saturation measurement a pour but (attribut) à visée diagnostique false Inferred relationship Some
Oxygen saturation measurement Has measured component Hydrogen ion concentration (observable entity) false Inferred relationship Some
Oxygen saturation measurement Has measured component oxygène false Inferred relationship Some
Oxygen saturation measurement est un(e) (attribut) Protein measurement true Inferred relationship Some
Oxygen saturation measurement élément (attribut) Oxyhemoglobin true Inferred relationship Some 1
Oxygen saturation measurement méthode (attribut) action : mesure true Inferred relationship Some 1
Oxygen saturation measurement Scale type (attribute) quantitatif true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Jugular bulb oxygen saturation measurement est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Invasive oxygen saturation monitoring (regime/therapy) est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Blood oxygen saturation (calculated) (procedure) est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Fluoroscopic angiography of right side of heart with contrast for oxygen saturation measurement a pour objet (attribut) True Oxygen saturation measurement Inferred relationship Some 2
Elevation of SaO2 interprète (attribut) True Oxygen saturation measurement Inferred relationship Some 1
Elevation of SaO2 interprète (attribut) False Oxygen saturation measurement Inferred relationship Some 1
Finding of oxygen saturation (finding) interprète (attribut) True Oxygen saturation measurement Inferred relationship Some 1
Oxygen saturation within reference range (finding) interprète (attribut) True Oxygen saturation measurement Inferred relationship Some 1
Oxygen saturation below reference range (finding) interprète (attribut) True Oxygen saturation measurement Inferred relationship Some 1
Venous oxygen saturation measurement est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Mixed venous oxygen saturation measurement est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Capillary oxygen saturation measurement est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Measurement of oxygen saturation at periphery est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Overnight pulse oximetry est un(e) (attribut) False Oxygen saturation measurement Inferred relationship Some
Oxygen saturation measurement, arterial est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some
Intracardiac oxygen saturation measurement est un(e) (attribut) True Oxygen saturation measurement Inferred relationship Some

This concept is not in any reference sets

Back to Start