FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

716152007: Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3304906014 Doppler ultrasound scan measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
4672982019 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
4672983012 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Is a Doppler ultrasonography of artery of lower limb (procedure) true Inferred relationship Some
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Is a Measurement of segmental blood pressure of artery of limb using Doppler ultrasonography (procedure) true Inferred relationship Some
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method Ultrasound imaging - action (qualifier value) false Inferred relationship Some 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site - Direct (attribute) Structure of artery of lower limb (body structure) true Inferred relationship Some 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Using device (attribute) Doppler device false Inferred relationship Some 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method Doppler ultrasound imaging - action (qualifier value) true Inferred relationship Some 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method Measurement - action true Inferred relationship Some 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site - Direct (attribute) Structure of artery of lower limb (body structure) true Inferred relationship Some 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method Examination - action true Inferred relationship Some 3
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site Anatomical or acquired body structure (body structure) true Inferred relationship Some 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start