Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
118562013 | Replacement of automatic cardioverter/defibrillator, total system | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
118563015 | Replacement of AICD | en | Synonym (core metadata concept) | Active | Only initial character case insensitive (core metadata concept) | SNOMED CT core |
811531012 | Replacement of automatic cardioverter/defibrillator, total system (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
316971000077111 | remplacement d'un défibrillateur cardiaque automatique, dispositif en entier | fr | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Switzerland NRC maintained Module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Replacement of automatic cardioverter/defibrillator, total system | Is a | Revision of automatic implantable cardioverter/defibrillator | true | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Is a | Replacement of device | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Method | Maintenance - action | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Procedure site | Cardiac structure | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Procedure site | Heart structure | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Implantable defibrillator | true | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Method | Introduction - action (qualifier value) | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Method | Surgical action | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Method | Replacement - action | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Revision status | Revision - value | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Method | Management - action | false | Inferred relationship | Some | ||
Replacement of automatic cardioverter/defibrillator, total system | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Procedure device (attribute) | Device | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Procedure device (attribute) | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Procedure site - Indirect (attribute) | Heart structure | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Cardiac implant | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Revision status | Revision - value | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Method | Surgical action | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Direct device | Implantable defibrillator | false | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Revision status | Revision - value | true | Inferred relationship | Some | 1 | |
Replacement of automatic cardioverter/defibrillator, total system | Method | Surgical action | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets