Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
55544017 | Check artificial pacemaker for amperage threshold | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
764668017 | Check artificial pacemaker for amperage threshold (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
183751000077116 | vérification d'un stimulateur cardiaque pour seuil d'intensité de courant | fr | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Switzerland NRC maintained Module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Check artificial pacemaker for amperage threshold | Is a | Check artificial pacemaker | true | Inferred relationship | Some | ||
Check artificial pacemaker for amperage threshold | Is a | Maintenance procedure for cardiac pacemaker system | true | Inferred relationship | Some | ||
Check artificial pacemaker for amperage threshold | Method | Maintenance - action | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Procedure site | Cardiac structure | false | Inferred relationship | Some | ||
Check artificial pacemaker for amperage threshold | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Method | Management - action | false | Inferred relationship | Some | ||
Check artificial pacemaker for amperage threshold | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Procedure device (attribute) | Device | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Procedure device (attribute) | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Is a | Maintenance of device (procedure) | false | Inferred relationship | Some | ||
Check artificial pacemaker for amperage threshold | Procedure site - Indirect (attribute) | Heart structure | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Direct device | Cardiac implant | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Check artificial pacemaker for amperage threshold | Procedure device (attribute) | Cardiac pacemaker | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets