Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Repositioning of cardioverter/defibrillator pulse generator | Is a | Revision of automatic implantable cardioverter/defibrillator | true | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Is a | Reposition of cardiac pacemaker pocket | true | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Method | Maintenance - action | false | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Procedure site | Cardiac structure | false | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Surgical action | false | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Procedure site | Heart structure | false | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Implantable defibrillator | true | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Revision status | Revision - value | false | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Method | Management - action | false | Inferred relationship | Some | ||
Repositioning of cardioverter/defibrillator pulse generator | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Defibrillator | false | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Repositioning - action | false | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Procedure device (attribute) | Device | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Procedure device (attribute) | Cardiac pacemaker | false | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Procedure site - Indirect (attribute) | Heart structure | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Cardiac implant | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Cardiac pacemaker | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Maintenance - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Repositioning - action | true | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Defibrillator | true | Inferred relationship | Some | 1 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Surgical action | false | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Revision status | Revision - value | false | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Direct device | Implantable defibrillator | false | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Method | Surgical action | true | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Revision status | Revision - value | true | Inferred relationship | Some | 3 | |
Repositioning of cardioverter/defibrillator pulse generator | Procedure device (attribute) | Cardiac pacemaker | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Relocation of automatic implantable cardioverter/defibrillator | Is a | True | Repositioning of cardioverter/defibrillator pulse generator | Inferred relationship | Some |
This concept is not in any reference sets