Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Sep 2022. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
4008535012 | Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
4008536013 | Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
5584761000172117 | mise en place percutanée de prothèse dans un anévrisme du cerveau | fr | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | Belgian module (core metadata concept) |
2528921000172114 | fluoroscopisch geleid percutaan inbrengen van stent in aneurysma van hersenen | nl | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | Belgian module (core metadata concept) |
2528931000172112 | percutaan plaatsen van stent in aneurysma cerebri onder doorlichting | nl | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | Belgian module (core metadata concept) |
2528941000172117 | percutane insertie van stent in cerebraal aneurysma onder röntgendoorlichting | nl | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | Belgian module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Placement of stent | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Insertion of stent using fluoroscopic guidance (procedure) | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Angiography of vascular structure of head | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Fluoroscopic angiography with contrast (procedure) | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Fluoroscopy of head | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Implantation of soft tissue | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Intracranial procedure (procedure) | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Implantation to cardiovascular system | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Access | Percutaneous approach | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Direct device | Stent | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Indirect morphology | Aneurysm | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Procedure site - Direct (attribute) | Intracranial vascular structure | false | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Procedure site - Indirect (attribute) | Intracranial vascular structure | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Procedure site - Direct (attribute) | Intracranial vascular structure | true | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Procedure site - Indirect (attribute) | Intracranial vascular structure | true | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Indirect morphology | Aneurysm | true | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Access | Percutaneous approach | true | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Direct device | Stent | false | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Procedure on central nervous system | false | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Fluoroscopy guided insertion of stent into intracranial vascular structure with contrast | true | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Using substance (attribute) | Contrast media (substance) | true | Inferred relationship | Some | 1 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Is a | Intracranial aneurysm operation | true | Inferred relationship | Some | ||
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Method | Surgical insertion - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Percutaneous insertion of stent into aneurysm of cerebrum using fluoroscopic guidance with contrast (procedure) | Direct device | Vascular stent | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets