Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Jun 2022. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Is a | Insertion of renal artery stent (procedure) | true | Inferred relationship | Some | ||
Percutaneous transluminal insertion of stent into renal artery (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Direct device | Arterial stent | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Procedure site - Indirect (attribute) | Structure of renal artery | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Access | Percutaneous approach | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Direct device | Arterial stent | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Procedure site - Indirect (attribute) | Structure of renal artery | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Direct device | Arterial stent | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Access | Percutaneous approach | true | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Procedure site - Indirect (attribute) | Structure of renal artery | true | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Is a | Percutaneous transluminal insertion of peripheral stent into artery (procedure) | true | Inferred relationship | Some | ||
Percutaneous transluminal insertion of stent into renal artery (procedure) | Is a | Branches of abdominal aorta operations | false | Inferred relationship | Some | ||
Percutaneous transluminal insertion of stent into renal artery (procedure) | Is a | Retroperitoneal tissue operations | false | Inferred relationship | Some | ||
Percutaneous transluminal insertion of stent into renal artery (procedure) | Surgical approach (attribute) | Transluminal approach | true | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Method | Surgical insertion - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Percutaneous transluminal insertion of stent into renal artery (procedure) | Direct device | Renal artery stent | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Percutaneous transluminal balloon angioplasty with insertion of stent into renal artery (procedure) | Is a | True | Percutaneous transluminal insertion of stent into renal artery (procedure) | Inferred relationship | Some |
This concept is not in any reference sets