FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

313330006: Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
457218015 Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
710100015 Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
11342581000172118 réduction fermée d'une fracture intracapsulaire du col du fémur et fixation par DHS (dynamic hip screw) fr Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Belgian module (core metadata concept)
11342591000172115 réduction fermée d'une fracture intracapsulaire du col fémoral et ostéosynthèse interne par vis-plaque dynamique fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3158741000172117 gesloten repositie van intracapsulaire femurhalsfractuur en fixatie met dynamische heupschroef nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3158751000172115 gesloten reductie van intracapsulaire fractuur van femurhals en interne fixatie met dynamische heupschroef nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3158761000172118 gesloten reductie van intracapsulaire collumfractuur en interne fixatie met dynamische heupschroef nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a intervention chirurgicale du pelvis false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Fixation of fracture using dynamic compression system false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Operation on hip joint false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Procedure on thigh false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site Bone structure false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Method Implantation - action false Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Access Open approach false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site Structure of neck of femur false Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Method Fixation - action true Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Operation on trunk false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Hip joint implantation false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Thigh implantation false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Procedure on femur false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Reduction of fracture false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Method Reduction - action false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Procedure on hip joint false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Open reduction of fracture with internal fixation false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct device Orthopedic internal fixation system false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Open reduction of fracture with fixation false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Using Orthopedic internal fixation system false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Reduction procedure false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Open reduction with internal fixation false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct device Orthopedic internal fixation system false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Open reduction false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site - Direct (attribute) Structure of neck of femur false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Using device (attribute) Bone screw true Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Fixation of hip false Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Closed reduction of fracture of femur with internal fixation true Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Closed reduction of fracture of hip true Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Fixation of fracture using screws true Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Method Closed reduction - action (qualifier value) true Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct morphology Fracture true Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Direct morphology Fracture true Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site - Direct (attribute) Structure of neck of femur true Inferred relationship Some 1
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Procedure site - Direct (attribute) Structure of neck of femur true Inferred relationship Some 2
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a Operative procedure on hip (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start