FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

310441008: Buckling of sclera using explant (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
454014016 Buckling of sclera using explant en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
707001012 Buckling of sclera using explant (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5630471000172114 bouclage de sclère par explant fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
2637821000172111 cerclage van sclera met behulp van explantaat nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Buckling of sclera using explant Is a Scleral buckling true Inferred relationship Some
Buckling of sclera using explant Procedure site Retinal structure false Inferred relationship Some 3
Buckling of sclera using explant Method Buckling - action false Inferred relationship Some 3
Buckling of sclera using explant Method Buckling - action false Inferred relationship Some 2
Buckling of sclera using explant Method Repair - action false Inferred relationship Some 1
Buckling of sclera using explant Method Closure by buckling - action false Inferred relationship Some 3
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 1
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 2
Buckling of sclera using explant Has focus Retinal tear false Inferred relationship Some
Buckling of sclera using explant Method Surgical repair - action false Inferred relationship Some 2
Buckling of sclera using explant Has focus défaut rétinien false Inferred relationship Some
Buckling of sclera using explant Direct device Scleral buckle (physical object) false Inferred relationship Some
Buckling of sclera using explant Procedure site - Indirect (attribute) Retinal structure false Inferred relationship Some 3
Buckling of sclera using explant Has focus Retinal detachment false Inferred relationship Some
Buckling of sclera using explant Method Repair - action false Inferred relationship Some 3
Buckling of sclera using explant Direct morphology defect false Inferred relationship Some 3
Buckling of sclera using explant Is a Posterior segment of eye closure (procedure) false Inferred relationship Some
Buckling of sclera using explant Method Surgical action false Inferred relationship Some 2
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 1
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 2
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 1
Buckling of sclera using explant Procedure site Scleral structure false Inferred relationship Some 2
Buckling of sclera using explant Is a Photocoagulation to retina false Inferred relationship Some
Buckling of sclera using explant Procedure site - Direct (attribute) Retinal structure false Inferred relationship Some 2
Buckling of sclera using explant Procedure site - Direct (attribute) Scleral structure false Inferred relationship Some 3
Buckling of sclera using explant Procedure site - Direct (attribute) Scleral structure true Inferred relationship Some 4
Buckling of sclera using explant Method Closure by buckling - action true Inferred relationship Some 4
Buckling of sclera using explant Method Closure by buckling - action false Inferred relationship Some 2
Buckling of sclera using explant Is a Operation on retina false Inferred relationship Some
Buckling of sclera using explant Is a Repair of retina (procedure) false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Implantation of custodis eye Is a False Buckling of sclera using explant Inferred relationship Some
Buckling of sclera and local or encircling explant however further qualified Is a False Buckling of sclera using explant Inferred relationship Some

This concept is not in any reference sets

Back to Start