FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

266706003: Continuous electrocardiogram monitoring (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
397152019 Continuous ECG monitoring en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2972121016 Continuous electrocardiogram monitoring en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2972171018 Continuous electrocardiogram monitoring (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5869661000172113 électrocardiogramme continu (monitoring ECG) fr Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Belgian module (core metadata concept)
3196401000172119 continue ECG-bewaking nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Belgian module (core metadata concept)
3196411000172116 continue elektrocardiografische bewaking nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3196421000172114 continue cardiale bewakingstelemetrie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Continuous ECG monitoring Is a Electrocardiographic monitoring true Inferred relationship Some
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some
Continuous ECG monitoring Using Electrocardiographic monitor and recorder false Inferred relationship Some
Continuous ECG monitoring Method Investigation - action false Inferred relationship Some
Continuous ECG monitoring Has intent Diagnostic intent (qualifier value) false Inferred relationship Some
Continuous ECG monitoring Method Measurement - action false Inferred relationship Some
Continuous ECG monitoring Direct device Electrocardiographic monitor and recorder false Inferred relationship Some
Continuous ECG monitoring Using Electrocardiographic monitor and recorder false Inferred relationship Some 1
Continuous ECG monitoring Method Monitoring - action false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Procedure site - Direct (attribute) Structure of cardiovascular system (body structure) false Inferred relationship Some 1
Continuous ECG monitoring Using device (attribute) Electrocardiographic monitor and recorder false Inferred relationship Some 1
Continuous ECG monitoring Method Monitoring - action false Inferred relationship Some 1
Continuous ECG monitoring Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
Continuous ECG monitoring Using device (attribute) Electrocardiographic monitor and recorder false Inferred relationship Some 1
Continuous ECG monitoring Using device (attribute) Electrocardiographic monitor and recorder true Inferred relationship Some 1
Continuous ECG monitoring Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 1
Continuous ECG monitoring Method Monitoring - action true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Belgian subset for nursing in patient health records

Back to Start