252762003: Interference pattern electromyography analysis (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
376483012 Interference pattern EMG analysis en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2972523012 Interference pattern electromyography analysis en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2972702016 Interference pattern electromyography analysis (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2819241000172114 analyse van interferentiepatroon van EMG nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Belgian module (core metadata concept)
2819251000172111 analyse van interferentiepatroon van elektromyografie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Interference pattern EMG analysis Is a Quantitative EMG analysis true Inferred relationship Some
Interference pattern EMG analysis Procedure site Neuromuscular junction (cell structure) false Inferred relationship Some
Interference pattern EMG analysis Method Investigation - action false Inferred relationship Some
Interference pattern EMG analysis Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 1
Interference pattern EMG analysis Has intent Therapeutic false Inferred relationship Some
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site Skeletal muscle system structure (body structure) false Inferred relationship Some 3
Interference pattern EMG analysis Procedure site Peripheral nervous system structure true Inferred relationship Some 2
Interference pattern EMG analysis Procedure site Skeletal and/or smooth muscle structure (body structure) false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Procedure site Skeletal muscle structure (body structure) false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Using device (attribute) Electromyographic monitor and recorder false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site - Direct (attribute) Neuron-muscle motor unit false Inferred relationship Some 1
Interference pattern EMG analysis Procedure site - Direct (attribute) Structure of nervous system (body structure) false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 2
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 1
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action false Inferred relationship Some 2
Interference pattern EMG analysis Procedure site - Direct (attribute) Structure of nervous system (body structure) true Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 3
Interference pattern EMG analysis Using device (attribute) Electromyographic monitor and recorder true Inferred relationship Some 3
Interference pattern EMG analysis Method Evaluation - action true Inferred relationship Some 4
Interference pattern EMG analysis Using device (attribute) Electromyographic monitor and recorder true Inferred relationship Some 4
Interference pattern EMG analysis Procedure site - Direct (attribute) Structure of neuron-muscle motor unit (body structure) true Inferred relationship Some 4

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start