FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

179100002: Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
277120012 Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
562082018 Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3172001000172116 conversie naar interne fixatie van proximale femurfractuur met schroef of pen en intramedullair hulpmiddel zonder reductie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3172011000172118 conversie naar interne fixatie van fractuur van proximale femur met schroef of pen en intramedullair apparaat zonder reductie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
3172021000172111 conversie naar inwendige fixatie van proximale fractuur van dijbeen met schroef of pen en intramedullair hulpmiddel zonder repositie nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Revision screw fixation of fracture without reduction false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Procedure on thigh false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a intervention chirurgicale du pelvis false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Operation on hip joint false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site Structure of neck of femur false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Revision status Revision - value false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Implantation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Access Open approach false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site Bone structure false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Operative procedure on femur false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Thigh implantation false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Hip joint implantation false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Fixation of hip false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Internal fixation of femur false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Insertion - action (qualifier value) false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct device Bone screw false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using Orthopedic internal fixation system false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site Bone structure false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Operative procedure on femur false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using Bone screw false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct device Orthopedic internal fixation system false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 3
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Bone screw false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Structure of neck of femur false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Internal fixation of femur true Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Refixation false Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture true Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action true Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system true Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) true Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Revision status Revision - value true Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Revision true Inferred relationship Some
Revision to internal fixation(without reduction) of proximal femoral fracture with screw/nail and intramedullary device Is a Operative procedure on hip (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start