1204131005: Break of insulation of implantable cardioverter defibrillator ventricular lead (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Mar 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4954767018 Implantable cardioverter defibrillator ventricular lead insulation break en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4954833018 Break of insulation of implantable cardioverter defibrillator ventricular lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4954834012 Break of insulation of implantable cardioverter defibrillator ventricular lead (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
13766941000172116 breuk van isolatie van ventriculaire geleidingsdraad van implanteerbare cardioverter-defibrillator nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
13766951000172119 breuk van isolatie van ventriculaire elektrodedraad van implanteerbare cardioverter-defibrillator nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
13766961000172117 gebroken isolatie van ventriculaire lead van implanteerbare cardioverter-defibrillator nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) Belgian module (core metadata concept)
13766971000172114 breuk van isolatie van ventriculaire lead van ICD nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Belgian module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantable cardioverter defibrillator ventricular lead insulation break Is a Malfunction of implantable defibrillator ventricular lead (disorder) true Inferred relationship Some
Implantable cardioverter defibrillator ventricular lead insulation break Associated with Implantable defibrillator true Inferred relationship Some 1
Implantable cardioverter defibrillator ventricular lead insulation break Due to Procedure false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets