FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.24  |  FHIR Version n/a  User: [n/a]

68121006: bepalen van druk in interstitieel vocht in spiercompartiment (verrichting)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Nov 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
113154012 Measurement of interstitial fluid pressure in muscle compartment en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
807922017 Measurement of interstitial fluid pressure in muscle compartment (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3350721000146114 bepalen van druk in interstitieel vocht in spiercompartiment nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3350731000146111 bepalen van druk in interstitieel vocht in spiercompartiment (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3350741000146115 bepalen van druk in interstitiële vloeistof in spiercompartiment nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3350751000146117 bepalen van druk in weefselvocht in spiercompartiment nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


2 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of interstitial fluid pressure in muscle compartment Is a Procedure on muscle false Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Is a Measurement of interstitial fluid pressure true Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Procedure site Interstitial space false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Investigation - action false Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Has intent Diagnostic intent (qualifier value) false Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Procedure site Skeletal and/or smooth muscle structure (body structure) false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Is a Procedure on organ false Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Measurement - action false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Evaluation - action false Inferred relationship Some 2
Measurement of interstitial fluid pressure in muscle compartment Is a Anatomic measurement false Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment Procedure site - Direct (attribute) Skeletal and/or smooth muscle structure (body structure) false Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Method Measurement - action true Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Procedure site - Direct (attribute) Skeletal and/or smooth muscle structure (body structure) true Inferred relationship Some 1
Measurement of interstitial fluid pressure in muscle compartment Is a Procedure on muscle true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Measurement of interstitial fluid pressure in muscle compartment of upper extremity (procedure) Is a True Measurement of interstitial fluid pressure in muscle compartment Inferred relationship Some
Measurement of interstitial fluid pressure in muscle compartment of lower extremity (procedure) Is a True Measurement of interstitial fluid pressure in muscle compartment Inferred relationship Some

This concept is not in any reference sets

Back to Start