FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

448841009: vervanging van cardiale biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting (verrichting)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2019. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2898338012 Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2902346016 Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1408381000146117 vervanging van cardiale biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2539561000146113 vervanging van cardiale biventriculaire implanteerbare cardioverter-defibrillator onder röntgendoorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2539571000146119 fluoroscopisch geleide vervanging van cardiale tweekamer-ICD nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
2539581000146117 vervanging van cardiale biventriculaire implanteerbare cardioverter-defibrillator onder doorlichting nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of cardiac defibrillator using fluoroscopic guidance (procedure) true Inferred relationship Some
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Implantable defibrillator true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Replacement - action false Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 2
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of cardiac biventricular implantable cardioverter defibrillator (procedure) true Inferred relationship Some
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Surgical replacement - action true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Implantable defibrillator true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start