434392000: disfunctie van biventriculaire cardiale pacemaker (aandoening)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2008. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2744406014 Malfunction of biventricular cardiac pacemaker (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2769660017 Biventricular cardiac pacemaker malfunction en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2769661018 Malfunction of biventricular cardiac pacemaker en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
11211161000146118 disfunctie van biventriculaire cardiale pacemaker (aandoening) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11211171000146112 disfunctie van biventriculaire cardiale pacemaker nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11762441000146113 slecht functionerende biventriculaire hartpacemaker nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Malfunction of biventricular cardiac pacemaker (disorder) Is a Malfunction of cardiac pacemaker (disorder) true Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) Finding site Structure of cardiovascular system (body structure) false Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) After insertie van prothetisch implantaat false Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) After Implantation of cardiac resynchronization therapy implantable pacemaker true Inferred relationship Some 1
Malfunction of biventricular cardiac pacemaker (disorder) Associated with Cardiac pacemaker false Inferred relationship Some 3
Malfunction of biventricular cardiac pacemaker (disorder) Due to Procedure false Inferred relationship Some 2
Malfunction of biventricular cardiac pacemaker (disorder) Associated with Implant false Inferred relationship Some 4
Malfunction of biventricular cardiac pacemaker (disorder) Associated with Implantable cardiac pacemaker false Inferred relationship Some 2
Malfunction of biventricular cardiac pacemaker (disorder) Is a mechanische complicatie van implantaat (aandoening) false Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) Is a Disorder following clinical procedure false Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) Is a Postoperative complication (disorder) true Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) Is a mechanische complicatie van intracardiaal implantaat false Inferred relationship Some
Malfunction of biventricular cardiac pacemaker (disorder) Associated with Cardiac resynchronization therapy implantable pacemaker true Inferred relationship Some 2
Malfunction of biventricular cardiac pacemaker (disorder) Is a Complication associated with cardiac implant true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Malfunction of biventricular cardiac pacemaker battery Is a True Malfunction of biventricular cardiac pacemaker (disorder) Inferred relationship Some

This concept is not in any reference sets

Back to Start