FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

313886003: bepalen van prolactine in serum na 60 minuten (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
458056010 60 minute serum prolactin measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
458057018 60 minute serum prolactin level en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
710646016 60 minute serum prolactin measurement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3420141000146112 bepalen van prolactine in serum na 60 minuten nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3420151000146110 bepalen van prolactine in serum na 60 minuten (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3420161000146113 bepalen van PRL in serum na 60 minuten nl Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
3548321000146110 bepalen van lactogeen hormoon in serum na 60 minuten nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
60 minute serum prolactin measurement Is a Prolactin measurement false Inferred relationship Some
60 minute serum prolactin measurement Has intent Diagnostic intent (qualifier value) false Inferred relationship Some
60 minute serum prolactin measurement Has measured component Prolactin false Inferred relationship Some
60 minute serum prolactin measurement Method Investigation - action false Inferred relationship Some
60 minute serum prolactin measurement Component Prolactin false Inferred relationship Some 3
60 minute serum prolactin measurement Method Evaluation - action false Inferred relationship Some
60 minute serum prolactin measurement Method Measurement - action false Inferred relationship Some 2
60 minute serum prolactin measurement Is a Serum prolactin measurement true Inferred relationship Some
60 minute serum prolactin measurement Has specimen Serum specimen true Inferred relationship Some 1
60 minute serum prolactin measurement Method Measurement - action true Inferred relationship Some 1
60 minute serum prolactin measurement Component Prolactin true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start