FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

143161000146106: continue glucosemonitoring in interstitiële vloeistof met insertie van glucosesensor (verrichting)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Mar 2021. Module: SNOMED CT Netherlands NRC maintained module (core metadata concept)

Descriptions:

Id Description Lang Type Status Case? Module
11621531000146114 Continuous glucose monitoring of interstitial tissue fluid with sensor placement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
11621541000146118 Continuous glucose monitoring of interstitial tissue fluid with sensor placement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
12732021000146117 continue glucosemonitoring in interstitiële vloeistof met insertie van glucosesensor (verrichting) nl Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
12732031000146115 continue glucosemonitoring in interstitiële vloeistof met insertie van glucosesensor nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)
12732051000146114 continu monitoren van glucose in weefselvocht met plaatsing van glucosesensor nl Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Netherlands NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Using device (attribute) Blood glucose monitoring equipment true Inferred relationship Some 1
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Direct device Sensor device (physical object) true Inferred relationship Some 2
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Is a Insertion procedure (procedure) true Inferred relationship Some
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Has specimen Interstitial fluid specimen (specimen) true Inferred relationship Some 3
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Method Measurement - action true Inferred relationship Some 1
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Method Insertion - action (qualifier value) true Inferred relationship Some 2
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Is a Glucose measurement by monitoring device false Inferred relationship Some
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Component Glucose true Inferred relationship Some 4
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Is a Fluid sample glucose measurement (procedure) false Inferred relationship Some
Continuous glucose monitoring of interstitial tissue fluid with sensor placement Is a Measurement true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start